ALBUREX 20, 200g/l Solution for infusion Ref.[6104] Active ingredients: Albumin

Source: Medicines & Healthcare Products Regulatory Agency (GB)  Revision Year: 2018  Publisher: CSL Behring GmbH, Emil-von-Behring-Strasse 76, 35041, Marburg, Germany

Pharmacodynamic properties

Pharmacotherapeutic group: plasma substitutes and plasma protein fractions
ATC code: B05AA01

Human albumin accounts quantitatively for more than half of the total protein in the plasma and represents about 10% of the protein synthesis activity of the liver.

Physico-chemical data: human albumin 200 g/l has a corresponding hyperoncotic effect.

The most important physiological functions of albumin results from its contribution to oncotic pressure of the blood and transport function. Albumin stabilises circulating blood volume and is a carrier of hormones, enzymes, medicinal products and toxins.

Pharmacokinetic properties

Distribution

Under normal conditions, the total exchangeable albumin pool is 4–5 g/kg body weight, of which 40–45% is present intravascularly and 55–60% in the extravascular space. Increased capillary permeability will alter albumin kinetics and abnormal distribution may occur in conditions such as severe burns or septic shock.

Elimination

Under normal conditions, the average half-life of albumin is about 19 days. The balance between synthesis and breakdown is normally achieved by feedback regulation. Elimination is predominantly intracellular and due to lysosome proteases.

In healthy subjects, less than 10% of infused albumin leaves the intravascular compartment during the first 2 hours following infusion. There is considerable individual variation in the effect on plasma volume. In some patients the plasma volume can remain increased for some hours. However, in critically ill patients, albumin can leak out of the vascular space in substantial amounts at an unpredictable rate.

Preclinical safety data

Human albumin is a normal constituent of human plasma and acts like physiological albumin.

In animals, single dose toxicity testing is of little relevance and does not permit the evaluation of toxic or lethal doses or of a dose-effect relationship.

Repeated dose toxicity testing is impracticable due to the development of antibodies to heterologous protein in animal models.

To date, human albumin has not been reported to be associated with embryo-foetal toxicity, oncogenic or mutagenic potential.

No signs of acute toxicity have been described in animal models.

© All content on this website, including data entry, data processing, decision support tools, "RxReasoner" logo and graphics, is the intellectual property of RxReasoner and is protected by copyright laws. Unauthorized reproduction or distribution of any part of this content without explicit written permission from RxReasoner is strictly prohibited. Any third-party content used on this site is acknowledged and utilized under fair use principles.